Fire Protection Manifold

Parameters of Fire Protection Manifold

Manifolds for Fire Control

The fire sprinkler valve group is specially designed for fire protection systems, featuring two red stainless steel operating levers and a pressure gauge for monitoring system pressure. With a dual-interface design, the flow switch can be installed on either side of the pipe.

  • Model No.: JX-0706
  • Size: 1″,1-1/4″,1-1/2″,2″
  • Material: CW617N, CW614N
  • Finish: Nickel-plated finishing
  • Medium: Water
  • Handle material: steel level handle
  • Oring: NBR
  • Manifold Standards
  • BS2779,EN331,ISO228,DIN 259
  • Working Temperature: From -5 ℃ To +90 ℃
  • Seat Sealing Material: PTFE with EPDM
  • Thread connection: ISO228, BS2779, DIN 259
  • Quality/ Certifications;CE,ISO9001,ACS
  • Cartridge; Brass ball
  • Manifold operator; Handwheel, 24V/230V AC/DC Electric actuator
  • Nickname: Brass Hydrant manifold
  • Salt spray test; Acetic acid/ASS 24 hours
  • Working pressure: 400PSI

Additional information

Description

Brass Hydrant Fire Valve FXM thread 0955d Brass Hydrant Fire Valve

As a manual globe valve, the fire hydrant valve draws fire-fighting water from the main water supply system. It controls water flow via a red handwheel—rotating the handwheel counterclockwise activates the water flow in the system. Installed on the stairwell landings of each floor inside the building, it allows firefighters to connect fire hoses to the valve and deliver fire-extinguishing water to the fire scene

  • Model No.: JX-0955
  • Size: DN40, DN65
  • Pressure rating: 16bar
  • Finish: Sand blasted
  • Working temperature: -10-120℃
  • Material: Brass
  • Certification: ACS, NF
  • Medium: water
  • Connection: NPT, BSP/ISO228
  • Rotation: Rotating Bolt
  • Structure form: lifting rod type
 

Male Thread Connection Brass Fire Safety Sprinkler

Brass Fire Safety Sprinkler

The fire sprinkler head is a crucial component of the automatic fire suppression system. It is designed to spray water automatically when it detects signs of fire. The red liquid in the glass bulb gets bigger when it reaches a high enough temperature. This causes the bulb to break, triggering the water spraying. It is installed in warehouses, industrial buildings, and other places where fire control is the primary objective.

  • Model No.: JX-0807
  • Size: 1/2″
  • Material: Brass
  • Medium: Water
  • Certification: ASME, ANSI, DIN, JIS
  • It comes with a 1-year warranty
  • working pressure: 12bar
  • MAX temperature: 68℃
  • Transport Package: Carton box
  • Angle: 180 degrees
 

Manual Air Vent Valve Brass

Manual Air Vent Valve Brass

A brass air release valve, also known as a vent valve or air bleed valve, is used to manually discharge trapped air in pipelines or equipment. The knurled knob on the top enables manual operation, allowing excess air in the system to be released and preventing air blockage from affecting fluid flow. It is applied in central heating systems and radiators, HVAC systems, water supply pipelines, and water storage tanks.

  • Model No.: JX-0756
  • Size: 1/4″, 3/8″,1/2″
  • Material: Brass
  • Angle: 180 degrees
  • Connection: BSP, ISO228
  • Medium: Water
  • Max working pressure: 10bar
  • Max working temperatures: 120℃
  • For protecting piping materials and systems from corrosion due to air
  • Sandards: ASME, ANSI, DIN, JIS
brass nipple socket brass nipple socket

Maginot coupling is mainly used in the fire protection field. Featuring a symmetrical design, it enables quick and convenient connection and disconnection without precise alignment. It is used to connect fire hoses to fire hydrants, fire truck pumps, fire nozzles, and other fire-fighting equipment. It provides safe and easy connections in industrial facilities, ships, and offshore platforms.

  • Model No.: JX-0811
  • Size: DN40, DN60
  • Material: Aluminum alloy
  • Connection: BSP, BSTP
  • Max working pressure: 2.5MPa
  • Quick coupling connection
  • Foam, mixer, Water
  • Finishing: Original
  • With a 12-month warranty
  • Transport Package: Carton
 

Fire Inspector Test & Drain Valve

Special test and drain valve for fire sprinkler systems. This single-handle ball valve combines system testing and draining functions. It can perform regular tests by simulating the water flow required for fire scenarios, and discharge excess fluid in sprinkler pipes in a controlled way. It has a test position, a drain position, and a closed position. It is used to drain water in water supply mains or the entire wet sprinkler system. During system maintenance, it enables easy testing and efficient draining operations.

  • Model No.: JX-0954
  • Size: 1/2″
  • Material: Brass, lead-free brass
  • Connection: NPT, BSP
  • Working pressure: 16bar
  • Lightweight and compact design
  • Connection: NPT, BSP, ISO228
  • Finishing: Sand blasted
  • Transport Package: Packing Rxport Stand
  • Easy-to-use handle design for easy holding
  • Sprinkler installation: Upright
  • Medium: Water
1/2 bronze gate valve 3 way

 

Three-way Stop Fire-hydrant Valve

The three-way globe valve is used to control the flow direction of water, fuel, air, or gas in pipeline systems. It can realize fluid mixing, divert water flow to different outlets, or shut off the water flow of one or more interfaces. Equipped with three pipeline connection ports and a red handle, it adjusts or cuts off water flow by manually operating the internal mechanism. Suitable for installing water purifiers, ice makers, and other equipment, it can transform ordinary globe valves into functional three-way valves. Specific models can be used to control the water flow of fire hydrants

  • Model No.: JX-0852
  • Material: Bronze, lead-free brass
  • Temperature adjustment: 0-100℃
  • Size: DN15,DN20,DN25
  • Body material: Bronze
  • Stem: Rising stem
  • Standard installation of trim and drain valves for the fire sprinkler industry
  • Media: Water
  • Connection: BSP/ NPT, ASME
  • Finishing: Original, Sand blasted
  • Handle: Cast iron handle

FAQs of Manifolds for Fire Control

What is the core function of manifolds for fire control?

Its core function is to distribute firefighting water sources centrally. It provides liquid to multi-branch sprinklers, fire hydrants, or fire-extinguishing equipment simultaneously. It makes sure pressure is stable and flow is balanced at each terminal during firefighting.

What are the materials for fire control manifolds, and which industry standards must they comply with?

Plumberstar Prefers High-Corrosion-Resistance and high-strength carbon steel or stainless steel (such as 304/316). It must comply with fire protection industry standards such as NFPA 19 and GB 5135. Professional manufacturers will strictly control material testing to ensure structural integrity and service life in high-pressure and harsh environments.

How to Select a Fire Control Manifold for the Fire Protection System?

Pipe diameter is calculated based on total system flow rate, number of branches, single branch designed flow rate, and matched with system working pressure (commonly 1.6MPa/2.5MPa), providing system parameters for manufacturer customized selection to ensure compatibility.

Do fire control manifolds support customization of branch quantity, interface type, and installation method?

Plumberstar manufacturer can provide complete customization services. The number of branches can be designed as needed (commonly 2-12 branches). Interfaces can be threaded (NPT/BSP), flanged, or of other types. Installation methods include wall-mounted, vertical, and others, to adapt to different on-site layouts.

What is the core difference between fire control manifolds and ordinary industrial manifolds?

The core difference is that fire control manifolds must meet emergency reliability in fire scenarios, with a higher pressure rating, faster fluid response speed, and all components must pass fire-specific certifications. Regular manufacturers will strictly implement this standard to avoid flammable or failure-prone risks.

How to choose a manufacturer’s reliable qualifications?

You need to check if the manufacturer has a fire product production license. You also need to check if it has an ISO quality system certification. You need to check if the product comes with a certificate of conformity. You also need to check if it comes with a test report.

What key construction specifications must be followed during the installation of fire control manifolds?

It is necessary to ensure the installation surface is flat and firm, the interface is tightly sealed, and avoid pipeline stress transmitting to the valve body; branch connection must be constructed according to the designed flow direction, and a pressure test should be conducted after installation (qualified standards refer to the manufacturer’s requirements). Illegal modification is strictly prohibited.

How is the packaging of fire control manifolds?

The manufacturer uses customized packaging. The outer layer is a strong corrugated carton or plywood box. The inside is fixed firmly with EPE pearl cotton and foam. Key interfaces have protective caps. It also has moisture-proof film to prevent rust.

Does the manufacturer provide documentation support for customs clearance?

Yes. The destination country or region has requirements. The manufacturer will provide a full set of customs clearance documents. These documents include a commercial invoice, a packing list, a certificate of origin, a product test report, a fire certification certificate, and so on.

Recommend to Read

Get quote Now

Free Sample with OEM