Regulating Balance Flow Meter Valve

Regulating Balance Flow Meter Valve

The Orifice Double Regulating Balance Flow Meter Valve with Circuit is a precision instrument used to measure and regulate fluid flow in a system.

Materials:

CW617N, H58-3, Lead-free brass

Finising:

Sand blasted, Sand blasted and Nickel plated

Size:

1", 1/2", 3/4"

Thread connection

BSP, NPT

Working pressure

8 bar

MOQ:

500pcs

Lead time:

45 days

Warranty:

24 months

Orifice Double Regulating Balance Flow Meter Valve with Circuit

JX-0942

Balancing Valves
Customized support: OEM, ODM, OBM
The temperature of Media: Medium Temperature
Power: Manual
Media: Water
Single gross weight: 0.200 kg
Package-Type:
1/2″ flow meter, brass solar balancing ball valve. Packing: Plastic bag, carton
1/2″ 3/4″ 1.”
Brass/Nickel Plating
Connection Male & Female Thread: BSP
Working Temperature
-20 ℃ to 120 ℃
Medium Oil, Gas, Water
Test Pressure: 0.6MPa – 0.8MPa by air

The orifice double regulating balance flow meter valve with the circuit is a precision instrument used to measure and control the flow of liquids and gases. It features two regulating valves that allow for fine-tuning of the flow rate. This makes it an ideal choice for applications where precise control is required. The meter valve also has a built-in circuit that monitors and records the flow rate data. This information can be accessed at any time for analysis and troubleshooting purposes. The orifice double regulating balance flow meter valve with the circuit is essential for any process engineer or technician.

The Double Regulating Balance Flow Meter Valve with Circuit is perfect for regulating and measuring the flow of liquid or gas in various applications. It features two valves that can be independently adjusted to control the flow rate, making it a versatile tool for many different tasks. The meter valve also has a built-in circuit that monitors and records the amount of fluid that passes through, making it an ideal choice for industrial use. With its durable construction and easy-to-use design, this balance flow meter valve is perfect for any workspace.

The Orifice Double Regulating Balance Flow Meter Valve with Circuit is perfect for regulating the flow of liquids and gases. It is made with a brass body and a PTFE seat, making it durable and reliable. It also has two regulating valves that allow you to adjust the flow rate easily. This valve is ideal for various applications, including HVAC, process control, and laboratory settings.

The Regulating Balance Flow Meter Valve with Circuit is a precision instrument used to measure and regulate fluid flow in a system. It features two orifices, each of which can be independently controlled to allow for fine-tuning the flow rate. This makes it an ideal tool for systems that require precise regulation, such as laboratories and pharmaceutical plants. The valve is constructed from high-quality materials and is designed for long-term use. It also includes a circuit that monitors the pressure and temperature of the fluid system, providing added safety and convenience. Order your Orifice Double Regulating Balance Flow Meter Valve today!

FAQs

1. Is this Regulating Balance Flow Meter Valve suitable for both heating and cooling systems?

Yes, this Regulating Balance Flow Meter Valve is made for heating and cooling water systems. It works when the water temperature is between 5℃ and 120℃, and this range fully covers cool chilled water from 7-24℃ and hot heating water from 40-90℃. We test the valve by opening and closing it 10,000 times while running hot and cold water back and forth, and its flow reading error stays within ±5%. This performance meets the hydraulic balance accuracy requirements for HVAC systems.

2. Can you provide a full-dimensional drawing for the Regulating Balance Flow Meter Valve?

Plumberstar can supply full dimension drawings for this Regulating Balance Flow Meter Valve to match your project needs. We normally offer editable DWG CAD files and PDF engineering drawings. These files cover sizes DN15 to DN50.

The drawings show the valve’s total length (L), total height (H), the size of the inlet and outlet connections, where to put the flowmeter, handwheel size, and all the main assembly measurements. All this information helps you plan your pipe layout, pick the right parts, and check if you have enough room to install it.

Our standard outline dimensions follow the real production tolerances for our products. Important CNC-machined parts such as valve stems, threaded connections, and flowmeter mounting holes have stricter limits. We can set some tolerances between ±0.05 mm and ±0.10 mm to match what the structure needs. Tolerance numbers change based on the DN size and where you take the measurement. The official signed engineering drawing is what we use as the final standard. If you need 3D STEP files for your design or machine setup, just ask for them when you place your order.

3. What test port options are available for this Regulating Balance Flow Meter Valve?

Our Regulating Balance Flow Meter Valve has two standard G1/4 pressure tapping ports. These ports check pressure on the upstream and downstream sides of the valve separately, and users can hook up a differential pressure gauge during system commissioning. The measured ΔP value pairs with the Kv/Cv figures or flow curves matched to the valve opening, to work out and confirm the real flow rate inside the pipeline.

We can also supply custom G1/8 or 1/4″ NPT interfaces to fit measuring devices for different markets and clients. The 1/4″ NPT option works better for North American projects and systems built around NPT measurement connectors. Every pressure tapping port can get a protective cap; this cap seals the port while the system runs normally without differential pressure tests, and keeps dust and building waste out of the port.

4. Can you provide neutral packaging for this Regulating Balance Flow Meter Valve?

Regulating Balance Flow Meter Valve
Regulating Balance Flow Meter Valve

Sure, we offer neutral packaging options. Our standard neutral packaging uses cartons and inner packs with no brand marks. The cartons only carry basic product specification details, and there is no Plumberstar trademark printed on them. This setup lets customers resell the goods under their own brand names. We can send packaging samples so customers can check the look first. We can also add customers’ own logos and product details on these neutral cartons later if required, and we handle all that work!

5. Does the Regulating Balance Flow Meter Valve meet the European market?

This Regulating Balance Flow Meter Valve meets the basic requirements to sell for heating water systems all over Europe. Its valve body is made of CW617N brass, which complies with European brass standards. It works with water temperatures from 5℃ up to 120℃, perfect for normal European heating and chilled water systems. We test the valve for pressure according to EN 12266-1 standards. The valve body can withstand 1.5 times its rated pressure for 60 seconds; the seat seal gets a Class A rating with no visible leaks; and the error in its flow reading stays within ±5%.

You need to know one point. When this valve is used on special high-pressure, large-diameter pressure circuits in Europe, it needs a separate PED assessment. This assessment adds 15 to 25 days to the test timeline. Plumberstar can adjust nameplate details to match local rules for different EU countries. The nameplate lists pressure, temperature, model, and CE number, and we accept on-site sampling checks and verification by third-party organizations.

Materials:

CW617N, H58-3, Lead-free brass

Finising:

Sand blasted, Sand blasted and Nickel plated

Size:

1", 1/2", 3/4"

Thread connection

BSP, NPT

Working pressure

8 bar

MOQ:

500pcs

Lead time:

45 days

Warranty:

24 months

Scroll to Top

Get Quote Now

Free Sample with OEM