Facing a leaky ball valve stem? Although it is an annoying and costly issue, fixing it promptly will prevent further damage and thus will save your water bill. In this blog, we will guide you on how to correctly spot and repair a leaky ball valve by adhering to some easy and doable steps so that you can tackle this irritating problem as soon as possible.
What is a Ball Valve?
A ball valve controls the fluid’s flow by applying pressure on the ball, fitted into a cup-shaped opening. The position of the ball directs the opening or closing of the pathway.
Apart from being functional and widely applied in different plumbing systems, they require careful installation, which, if not done correctly, can cause leaky areas, resulting in malfunctioning ball valves. If you are also looking for a quick-fix method, keep reading; this article will give you all the required information on fixing ball valve leaks.
What is a Ball Valve Stem?
The stem of a ball valve regulates and controls the ball’s movement, resulting in the valve opening or closing. It is present at the top of the ball.
Causes of the Ball Valve Stem Leaks
To fix a leaky ball valve stem, it is important to know its causes, which can be categorized broadly into 4 factors.
-
Malfunctioning Ball Valve Stem
The malfunctioning ball valve stem leaks may be due to the following:
A: It can be due to the failure of stem packing that could be due to damage.
B: if it is not aligned properly, it will be rubbed against it, which eventually causes leaks.
C: if the valve is not installed properly, e.g., the connection has any gap, this can also cause leakage.
- Corrosion
If the stem of the ball valve erodes with time, it inhibits the ball’s rotation, which in turn causes the leakage of the ball valve stem. Choose an anti-corrosive material like stainless steel for the valve parts to prevent this.
- Lack of Lubricant
Lubrication is an essential factor to consider. In the case of not enough lubricant, it will result in damage due to the friction between the stem and other parts of the valve.
- Extreme Conditions
Extreme and unfavorable conditions also cause leakage in the ball valve stem, such as high temperature and pressure, which put stress on the valve stem and, as a result, cause leakage in the system.
So, pick an anti-corrosive material for the valve with a higher pressure rating.
How Do I Know If The Ball Valve Is Leaking?
If you observe these few signs, it means that your ball valve is leaking. Fixing them in the beginning will prevent the ineffectiveness of valves.
Case 1:
If the leakage is visible at the stem, you can quickly identify damage in the stem packing. The solution will include replacing the damaged part.
Case 2:
If you find it difficult to move or turn the valve, it is a sign of a problem inside the stem, which could be either its misalignment or damage obstructing the system. Fix the problem by repairing or replacing the worn-out parts.
Case 3:
If you hear any unusual sound with the movement of the valve, it is like an alarm for you to know that the parts are causing some friction and producing a specific sound. If you observe any of the above indications, you should not ignore them and try to fix them immediately to avoid a more significant issue with the plumbing system.
How to Repair a Leaking Ball Valve
Fixing a leaky ball valve is not a daunting and technical task, but it is a learning technique. Before starting, gather all the tools you require to avoid hassles at the last moment. For this, you will need:
- Adjustable wrench
- Screwdrivers
- Replacement washers or O-rings
- Pipe wrench (if dealing with large pipes)
- Teflon tape
- Bucket
- Towel
- Shut the water supply to inspect and know the exact leakage point. The inspection will include all the stem parts, i.e., its packing and nut and bolt, for any susceptible damage or corrosion.
- If the source of the leak is due to the loosening of your stem, you can quickly tighten the stem nut or bolt by using a wrench, as this will seal the gap in between to prevent leakage.
Pro Tip: In case of persistent leakage, check the gland nut, which is used to compress the stem packing, and tighten it in case of a loose connection.
iii. If the cause of your leakage is due to the stem packing damage, then you need to replace it. Replacement of the stem packing includes the following steps:
Remove any extra pressure put on the valve before replacing it; otherwise, serious damage could occur.
Remove all the parts of the stem, especially the valve actuator.
Slightly loose and remove the gland nut and take out the packing with the help of a hooked wire.
Install and align the new packing carefully to ensure proper sealing.
During the replacement, if you find any other corroded or worn-out parts, replace them, including the stem, nut, bolt, ball seats, etc.
- It’s time to reassemble and test the valve using the manufacturers’ instructions.
- Allow fluid flow and inspect and observe it closely for leaks or misalignment.
How to Select the Right Ball Valve?
For the ball valves to work flawlessly, proving their robust functionality, it is crucial to select them appropriately. Keeping in mind these points will make the whole process simple and hassle-free.
-
Size:
Looking for the perfect size of the ball valve is crucial as it needs to match the pipeline system and other end connections. If the size does not blend perfectly with the plumbing pipes and connections, it won’t allow smooth fluid transfer.
- Material:
You can select its material depending on the type of fluid your ball valve has to handle. The material of the stem, ball, and valve body determines its functionality and effectiveness. For example, silicon bronze is a corrosion-resistant material as compared to copper.
- Pressure and temperature:
It is also important that the ball valve you select should be capable of handling extreme temperatures and pressures. Select the materials that are perfect for handling extreme temperatures and pressures.
- Flow control:
Depending on the type of fluid and the precision needed to control the flow, select the appropriate kind of ball valve, i.e., v-port, full bore, or reduced ball valve.
Tips for Preventing Future Leaks:
How to Fix a Leaky Water Valve (Ball Valve) from Bootstrappin
- Regular Maintenance:
Through regular maintenance, future leaks can be prevented. Observe the stem, stem packing, and other valve parts thoroughly for any damage and replace them if needed.
- Installation or Alignment:
Check the installation of the valve, which should be done according to the manufacturer’s instructions. The alignment of the stem is also an essential factor, which, if not done correctly, can cause wear and tear, leading to damage and leaks.
- Lubrication
Ensure the valve stem and other parts are lubricated well for proper function. It will help with smooth movement and prevent future damage.
- Stem Extensions:
Stem extensions are an optional part of the valve that can be added to the stem in case of increased length requirement for easily operated movement.
- Installing Rising Stem:
The rising stem in the ball valve has a unique system that prevents the rotating motion of the stem; instead, it moves it in linear motion and simultaneously rotates the ball. The advantage of this rising stem is that it prevents stem damage by rotating motion. It also helps to reduce friction due to its linear motion.
Final Remarks:
Fixing a ball valve stem leak is a straightforward task you can easily do by following the mentioned steps, saving you time and money. Gathering all the required tools and items can fix an early issue for your effective functionality and longevity.
Still, if you need assistance or help, don’t hesitate to contact professional support. For likewise assistance and queries, you can contact plumberstar.com
FAQs
How Do You Stop A Valve Stem From Leaking?
You can stop a valve stem from leaking by replacing the stem packing, valve stem, or seals. Also, inspect the nuts and bolts, and if there is a loose connection, tighten the nut, bolt, and gland nut.
What Type of Seal Is Used in the Ball Valve?
Teflon or virgin PTFE is used as a seal material in ball valves. It can handle pressure under 5 KS and temperatures ranging from -20F to 400F.